OEM/ODM Manufacturer Constant Voltage Led Driver - LED Emergency Driver Lasting 3 Hours – SASELUX
OEM/ODM Manufacturer Constant Voltage Led Driver - LED Emergency Driver Lasting 3 Hours – SASELUX Detail:
- This emergency kit provides
60-180 Minutes duration in the event of a power failure. Suit for LED luminaire with external driver 100W or below.
- Lithium iron phosphate Battery backup
IFR18650MUB 3.2V 1500mAh battery cell,
- Output: DC10-50V. 50-200V Constant power 2-6W
Dimension

-Automatic self-test function
-Status of the battery.
-Status of the LED
-Charge condition
-Duration test
-Functional test
Application
-LED Downlight, Tri-proof, Linear LED light fixture
Battery pack

There are three combinations of batteries. Please ask the service commissioner for the specifications.
|
Model |
Output Constant power |
Battery backup |
Duration |
| CK-7091L | DC 10-50V 6W |
LiFePO4 6.4V 1.5AH |
1 hour |
| CK-7091H | DC 50-200V 6W |
LiFePO4 6.4V 1.5AH |
1 hour |
| CK-7092L | DC 10-50V 3W |
LiFePO4 6.4V 1.5AH |
2 hours |
| CK-7092H | DC 50-200V 3W |
LiFePO4 6.4V 1.5AH |
2 hours |
| CK-7093L | DC 10-50V 4W |
LiFePO4 6.4V 1.5AH |
1.5 hours |
| CK-7093H | DC 50-200V 4W |
LiFePO4 6.4V 1.5AH |
1.5 hours |
| CK-7094L | DC 10-50V 2W |
LiFePO4 6.4V 1.5AH |
3 hours |
| CK-7094H | DC 50-200V 2W |
LiFePO4 6.4V 1.5AH |
3 hours |
| CK-7095L | DC 10-50V 4W |
LiFePO4 6.4V 3.0AH |
3 hours |
| CK-7095H | DC 50-200V 4W |
LiFePO4 6.4V 3.0AH |
3 hours |
Automatic self-test function
LED status display
Functional test
Connecting battery firstly, connecting mains supply then, this emergency conversion module will automatically go into emergency mode and discharge for 3 seconds.
Timer stats to calculate when battery is fully charged for the very first time.
The emergency conversion module will automatically discharge 10 seconds every 30 days as a short time functional test.
Duration test
Emergency conversion module will automatically discharge 90 minutes every 180 days.
If a mains supply failure occurs at any time, before or during functional test and duration test period, emergency conversion module will go into emergency mode immediately. Timer would not re-calculate if battery is not disconnected after emergency mode. If the battery is disconnected, timer will re-calculate.
The test switch and indicator light are connected through a plug on the inverter.
Product detail pictures:
Related Product Guide:
"Sincerity, Innovation, Rigorousness, and Efficiency" may be the persistent conception of our organization for that long-term to establish jointly with customers for mutual reciprocity and mutual gain for OEM/ODM Manufacturer Constant Voltage Led Driver - LED Emergency Driver Lasting 3 Hours – SASELUX , The product will supply to all over the world, such as: Bangladesh, Leicester, Barbados, In order to make more people know our products and to enlarge our market, we have devoted a lot of attention to technical innovations and improvement, as well as replacement of equipment. Last but not the least, we also pay more attention to training our managerial personnel, technicians and workers in planned way.